Jef Driesen 255a2dbb9a Keep open-circuit and diluent gas mixes separately
The OSTC stores either the OC gas mixes or the CCR diluents depending on
the dive mode. For CCR dives, there is also bailout to an OC gas
possible, and those gas mixes are added dynamically to the manual gas
mixes.

The Shearwater dive computers store both the configured OC gas mixes and
CCR diluents in the header.

In both cases, the gas change events should reference the correct type
of gas mix. This patch takes care of that.