Several dive computers support multiple transports. For example the
Suunto Eon Steel supports both USB HID and BLE. All devices using
bluetooth classic communication support both the native bluetooth
transport and the legacy serial port emulation.
To support this feature, the values of the dc_transport_t type are
changed into bitmasks, and the dc_descriptor_t struct is extended with a
bitfield with all the supported transports.
The device descriptors are extended with a filter function. During the
device discovery, this filter function is used to return only devices
that match a known dive computer.
The filtering is optional, and can be disabled by passing a NULL pointer
for the device descriptor when creating the iterator with one of the
dc_xxx_iterator_new() functions.
Unlike the Shearwater Petrel, the Shearwater Nerd 2 appears to have a
distinct model number from the Nerd.
Reported-by: Janice McLaughlin <janice@moremobilesoftware.com>
The Suunto Eon Core uses a different USB PID, but otherwise it's
compatible with the Eon Steel. It's probably an Eon Steel internally,
but with a smaller form factor.
To be able to distinguish between the two models and use the correct USB
PID, each model is assigned a different (artificial) model number.
Reported-by: Nick Shore <support@mac-dive.com>
The model number is stored in the final block of each dive. But for an
efficient implementation of the fingerprint feature, the devinfo event
should be emitted before downloading the manifests or the dives. Thus
reporting the correct model number is problematic.
Currently the model number is simply hardcoded to the value of the
Petrel. This is sufficient for the parser, because there the model
number is only used to distinguish the Predator from all the other
models. Now, because the petrel backend doesn't support the Predator,
and the predator backend (which supports both the Predator and Petrel)
can obtain the correct model number from the final block, the hardcoded
value works fine. Except of course for identifying the actual model!
Allthough there doesn't seems to be a command to retrieve the model
number directly, we can retrieve the hardware type and map that to the
model number.
The communication protocol is identical to the G2 protocol, but with a
different USB VID/PID (c251:2006).
Note that unlike the G2, the Aladin Square seems to support only 33 byte
USB HID packets (1 byte report id and 32 bytes payload), even when the
actual command is much smaller. Without padding the commands, the dive
computer doesn't reply at all. Because the padding is already there, to
support the Windows api, no further changes are necessary.
At the time support for the Orca and iDive series was implemented, they
were being sold under the "DiveSystem" brand. But nowadays, the newer
iDive and iX3M series are being sold under the "Ratio" brand. Since this
frequently confuses end-users, let's rename the libdivecomputer vendor
name as well.
The Orca and the original iDive series remain under the DiveSystem
brand.
On Windows, the hidapi library uses the standard Microsoft USB HID
driver, while libusb requires the installation of a different driver
(WinUSB or libusbK). But installing one of the libusb drivers breaks
compatibility with other applications using hidapi (Scubapro LogTRAK and
Suunto DM5) because only one driver can be active. Switching
libdivecomputer to hidapi avoids this problem.
On Linux, the hidapi library doesn't seem to offer any advantages over
libusb. Most distributions don't even have the hidapi library installed
by default. Because there are usually two variants of the hidapi library
available on Linux (hidapi-libusb and hidapi-hidraw), the autotools
build system won't be able to detect it out-of-the-box, and will
automatically fallback to the libusb implementation.
On Mac OS X, hidapi is already the default (and also the only option).
The correct name for the OSTC 3+ is OSTC Plus nowadays. Allthough the
exact name doesn't really matter because all OSTC3 based models are
compatible, using the correct name should reduce confusing for
end-users.
The Cochran Commander TM appears to be a first generation Commander with
limited storage and function compared to later models.
The main differences are:
- The TM doesn't support high-speed transfer so use the 0x05 read
command and don't change to a higher baud rate. Still reset to 9600
to wait for the heartbeat.
- The TM has a different config command (one byte).
- The TM has only one config page.
This adds support for older Cochran Commander dive computers,
specifically Commanders with serial numbers prior to 21000.
This also renames "Commander" model to "Commander II" and
adds "Commander I" to refer to pre-21000 models.
The back-end parser seems to be the same as for the Uwatec Smart (aka
Galileo Sol). At least that's the assumption right now.
The downloader just uses USB HID (very similar to EON Steel) rather than
the horrible IrDA thing.
There's also eventually a BLE thing, but that's for the future.
This is an unholy mixture of the Uwatec Smart downloader logic and the
EON Steel usbhid transfer code. The back-end is pure Uwatec Smart
(model 0x11, same as Galileo Sol).
I'm not at all sure this gets everything right, but it downloads
*something*.
[Jef Driesen: Renamed the backend to uwatec, and made some smaller
cosmetic changes to match the existing coding style.]
Signed-off-by: Linus Torvalds <torvalds@linux-foundation.org>
The dummy IrDA implementation is integrated in the main file. The
appropriate implementation is selected using conditional compilation
based on the features detect by the autotools build system.
The Cressi Drake is a mainly a freedive computer. The data format is
almost identical to the Leonardo. The main difference is that a single
dive now contains an entire freedive session. Each freedive in the
session is delimited with a 4 byte header containing the surface
interval and a special marker.
The Aeris 500AI is quite different from the other vtpro compatible
models. First, it uses the INTR protocol variant. Next, it doesn't
appear to have a logbook ringbuffer. Instead it supports a new read
logbook index command (0x52) that returns the logbook entries. This
requires a custom implementation of the logbook function.
The protocol of the iX3M series is almost identical to the protocol of
the iDive series. The main difference is that the command bytes and the
size of the response packets have been changed. In order to be able to
communicate with the correct set of commands, the user needs to supply
the correct number now. To maintain backwards compatibility, a new
variant of the open function is added.