8 Commits

Author SHA1 Message Date
Jef Driesen
4b541d124f Add support for the native Shearwater Petrel protocol.
The Petrel (with updated firmware) supports an enhanced communication
protocol, which is more efficient and powerfull than the legacy Predator
compatibility mode. The new protocol uses data compression for faster
transfers and supports the ability to selectively download individual
dives. Last but not least, the new protocol isn't limited to the last
128kB of logbook data, but can access the full logbook capacity (16MB).
2013-04-19 21:31:28 +02:00
Jef Driesen
6419e189a4 Add a single isinstance function per object type.
Currently, each backend has it's own function to verify whether the
object vtable pointer is the expected one. All these functions can be
removed in favor of a single isintance function in the base class,
which takes the expected vtable pointer as a parameter.

Functions which are called through the vtable, don't need to verify the
vtable pointer, and those checks are removed.
2013-04-16 12:18:54 +02:00
Jef Driesen
007479fc92 Rename the backend structure to vtable.
The term "backend" can be confusing because it can refer to both the
virtual function table and the device/parser backends. The use of the
term "vtable" avoids this.
2013-04-16 12:18:53 +02:00
Dirk Hohndel
3917ae15b9 Convert decostop / ndl to samples
Having these as events seems less useful since for many dive computers
there are data with every sample - so it makes much more sense to have
these as part of the sample.

Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
2012-12-11 20:38:08 +01:00
Dirk Hohndel
f2a656246d Add support for setpoint, ppO2 and CNS
So far only OSTC and Shearwater Predator are supported. For the OSTC we
support CNS and setpoint changes in the samples (the current hardware
doesn't actually support ppO2 sensors and for the older hw that does I
don't have the correct encoding information).

For the Predator we support only the "average ppO2 during the sample".

The Predator also gives us a CNS value at the end of the dive - I don't
quite know yet how to deliver that back to the consumer. Possibly as CNS
value in the very last sample? That would at least be consistent.

Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
2012-12-10 21:23:48 +01:00
Jef Driesen
f5b5e41181 Reduce the amount of gaschange events.
Previously, gaschange events were emitted for every single sample.
With this change, the event is only emitted when the gas mix has
actually changed.
2012-12-06 20:08:22 +01:00
Jef Driesen
99fe2c693f Support both the OC and CC gas mixes.
The Shearwater Predator has two different sets of gas mixes for OC
(Open Circuit) and CC (Closed Circuit) mode. Since the dive mode can
be switched during the dive (e.g. in a bailout scenario), there is no
easy way to select one of both sets. With this change, both sets are
returned. It's not a perfect solution, but for CC dives it's already
an improvement.
2012-12-06 20:01:46 +01:00
Jef Driesen
500fb1e16b Add support for the Shearwater Predator. 2012-12-05 16:08:47 +01:00