15 Commits

Author SHA1 Message Date
Jef Driesen
9b7aa813e0 Change the salinity format in the xml output
Replace the numeric type with a name (fresh or salt) and change the
density value into an xml attribute. The type is the primary
information here, while the density value is optional.
2023-05-16 13:48:49 +02:00
Jef Driesen
4e24b3a277 Pass the sample struct by reference
Because the sample struct is passed by value, the size of the structure
can't be changed without also changing the function signature and
breaking backwards compatibility. This prevents adding new fields in the
future, to support some new features.

When passing the sample struct by reference using a pointer, the size of
the pointer does always remains the same.
2023-05-15 22:19:36 +02:00
Jef Driesen
becb8bd36e Add a usage field to the tank and gas mix
For gas consumption calculations it's very convenient to know whether a
tank is used for example in a sidemount configuration, or as
oxygen/diluent tank on a rebreather.

For rebreather dives, it's convenient to know whether a gas mix is used
as a closed-circuit mix (oxygen/diluent) or as an open circuit mix
(bailout).
2023-05-15 22:19:36 +02:00
Jef Driesen
4b383a778e Add a TTS field to the deco sample
Some dive computers report the time of the next decompression stop,
while others report the Time To Surface (TTS). Some models can even
report both.

Add a TTS field to the deco sample to support both values.
2023-05-15 22:19:36 +02:00
Jef Driesen
b1ff2c6a8e Add the sensor index to the ppO2 sample
Rebreathers typically support multiple ppO2 sensors as a safety measure
in case a sensor fails during the dive. The current api can already
report multiple ppO2 values per sample, but it does not provide any
information about which sensor the measurement is from.

The new sensor index provides this info, and can also be used to
distinguish between the average/voted ppO2 value using the special value
DC_SENSOR_NONE.
2023-05-15 22:19:36 +02:00
Jef Driesen
a34e909a84 Change the units for the sample time to milliseconds
Some dive computers, especially freediving computers, supports multiple
samples per second. Since our smallest unit of time is one second, we
can't represent this, and the extra samples are dropped. Therefore, the
units are changed to milliseconds to prepare supporting this extra
resolution.
2023-05-15 22:19:34 +02:00
Jef Driesen
7fb943ae7f Add support for parsing the decompression model
Report the decompression algorithm (Buhlmann, VPM, RGBM or DCIEM), and
if available also the parameters. For now only the conservatism setting
is supported, and for the Buhlmann algorithm also the Gradient Factors
(GF).
2022-08-11 17:35:03 +02:00
Jef Driesen
82c0134811 Fix the timezone offset in the xml output
For negative timezone offsets, only the hour part should have a sign.
The minute part must always be formatted as a positive number.
2022-05-23 12:13:49 +02:00
Jef Driesen
6085a11b1f Add the average depth to the xml output 2018-06-22 23:14:15 +02:00
Jef Driesen
f87720dff9 Add support for semi-closed circuit diving
Add a new type to distinguish between closed circuit (CCR) and
semi-closed circuit (SCR) diving. Some dive computers from HW and
DiveSystem/Ratio support this.

Because the CCR/SCR abbreviations are more commonly used, let's take the
opportunity to also rename the existing DC_DIVEMODE_CC. To preserve
backwards compatibility, a macro is added to map the old name to the new
one.

Reported-by: Jan Mulder <jlmulder@xs4all.nl>
2017-11-30 09:03:46 +01:00
Jef Driesen
68380b2ec0 Fix some casts with constant pointers
Casting away the const qualifier generates a compiler warning which can
easily be avoided by preserving the const qualifier.
2017-11-24 23:45:11 +01:00
Jef Driesen
156f54302d Add basic timezone support
Allthough most dive computers always use local time and don't support
timezones at all, there are a few exceptions. There are two different
sources of timezone information:

 - Some of the newer Uwatec/Scubapro devices use UTC internally and also
   support a timezone setting. This UTC offset is currently taken into
   account to obtain the dive date/time, but the UTC offset itself is
   lost.

 - Uwatec/Scubapro and Reefnet devices rely on the clock of the host
   system to synchronize the internal device clock and calculate the
   dive date/time. The consequence is that the resulting date/time is
   always in the timezone of the host system.

In order to preserve this timezone information, the dc_datetime_t
structure is extended with a new "timezone" field, containing the UTC
offset in seconds. Devices without timezone support will set the field
to the special value DC_TIMEZONE_NONE.

The dc_datetime_localtime() and dc_datetime_gmtime() functions will
automatically populate the new field with respectively the local
timezone offset and zero. The dc_datetime_mktime() function will take
into account the new timezone field for the conversion to UTC. The
special value DC_TIMEZONE_NONE is interpreted as zero.
2017-08-18 23:26:45 +02:00
Jef Driesen
469717a2a1 Add support for imperial units in the xml output.
Libdivecomputer always uses metric units internally. But when reverse
engineering a device that stores everything using imperial units, it's
very convenient to be able to switch the output to imperial units too.
2016-03-29 16:34:27 +02:00
Jef Driesen
8ab3fb0542 Always close the xml tags.
The dive and sample xml tags were not closed properly if an error
occurred during parsing.
2016-03-27 22:02:52 +02:00
Jef Driesen
e35f0a3ff4 Add support for the xml output format.
The XML output format exports all dives to a single xml file.
2016-02-26 08:23:45 +01:00