Add support for multiple tank transmitters
The Ratio dive computers support up to 10 tank pressure sensors. The ID of the active tank sensor is stored in the sample data, and gets mapped to the corresponding tank index.
This commit is contained in:
parent
1cd285a4d8
commit
dc508c30f9
@ -39,7 +39,7 @@
|
||||
#define SZ_SAMPLE_IX3M_APOS4 0x40
|
||||
|
||||
#define NGASMIXES 8
|
||||
#define NTANKS 1
|
||||
#define NTANKS 10
|
||||
|
||||
#define EPOCH 1199145600 /* 2008-01-01 00:00:00 */
|
||||
|
||||
@ -58,6 +58,7 @@ typedef struct divesystem_idive_gasmix_t {
|
||||
} divesystem_idive_gasmix_t;
|
||||
|
||||
typedef struct divesystem_idive_tank_t {
|
||||
unsigned int id;
|
||||
unsigned int beginpressure;
|
||||
unsigned int endpressure;
|
||||
} divesystem_idive_tank_t;
|
||||
@ -126,6 +127,7 @@ divesystem_idive_parser_create (dc_parser_t **out, dc_context_t *context, unsign
|
||||
parser->gasmix[i].helium = 0;
|
||||
}
|
||||
for (unsigned int i = 0; i < NTANKS; ++i) {
|
||||
parser->tank[i].id = 0;
|
||||
parser->tank[i].beginpressure = 0;
|
||||
parser->tank[i].endpressure = 0;
|
||||
}
|
||||
@ -153,6 +155,7 @@ divesystem_idive_parser_set_data (dc_parser_t *abstract, const unsigned char *da
|
||||
parser->gasmix[i].helium = 0;
|
||||
}
|
||||
for (unsigned int i = 0; i < NTANKS; ++i) {
|
||||
parser->tank[i].id = 0;
|
||||
parser->tank[i].beginpressure = 0;
|
||||
parser->tank[i].endpressure = 0;
|
||||
}
|
||||
@ -368,6 +371,8 @@ divesystem_idive_parser_samples_foreach (dc_parser_t *abstract, dc_sample_callba
|
||||
unsigned int he_previous = 0xFFFFFFFF;
|
||||
unsigned int mode_previous = INVALID;
|
||||
unsigned int divemode = INVALID;
|
||||
unsigned int tank_previous = INVALID;
|
||||
unsigned int tank_idx = INVALID;
|
||||
|
||||
unsigned int firmware = 0;
|
||||
unsigned int apos4 = 0;
|
||||
@ -502,16 +507,39 @@ divesystem_idive_parser_samples_foreach (dc_parser_t *abstract, dc_sample_callba
|
||||
|
||||
// Tank Pressure
|
||||
if (samplesize == SZ_SAMPLE_IX3M_APOS4) {
|
||||
unsigned int id = data[offset + 47] & 0x0F;
|
||||
unsigned int pressure = data[offset + 49];
|
||||
if (tank[0].beginpressure == 0 && pressure != 0) {
|
||||
tank[0].beginpressure = pressure;
|
||||
ntanks = 1;
|
||||
|
||||
// Get the index of the tank.
|
||||
if (id != tank_previous) {
|
||||
unsigned int i = 0;
|
||||
while (i < ntanks) {
|
||||
if (id == tank[i].id)
|
||||
break;
|
||||
i++;
|
||||
}
|
||||
|
||||
tank_previous = id;
|
||||
tank_idx = i;
|
||||
}
|
||||
if (tank[0].beginpressure) {
|
||||
sample.pressure.tank = 0;
|
||||
|
||||
// Add a new tank if necessary.
|
||||
if (tank_idx >= ntanks && pressure != 0) {
|
||||
if (tank_idx >= NTANKS) {
|
||||
ERROR (abstract->context, "Maximum number of tanks reached.");
|
||||
return DC_STATUS_DATAFORMAT;
|
||||
}
|
||||
tank[tank_idx].id = id;
|
||||
tank[tank_idx].beginpressure = pressure;
|
||||
tank[tank_idx].endpressure = pressure;
|
||||
ntanks = tank_idx + 1;
|
||||
}
|
||||
|
||||
if (tank_idx < ntanks) {
|
||||
sample.pressure.tank = tank_idx;
|
||||
sample.pressure.value = pressure;
|
||||
if (callback) callback (DC_SAMPLE_PRESSURE, sample, userdata);
|
||||
tank[0].endpressure = pressure;
|
||||
tank[tank_idx].endpressure = pressure;
|
||||
}
|
||||
}
|
||||
|
||||
|
||||