Use the GTR mode to detect sidemount tanks
Firmware v84 introduced support for sidemount diving. Users can now configure the two sidemount tanks as the source for the GTR (Gas Time Remaining) estimations. We can take advantage of this feature to detect the sidemount tanks. This is more reliable than using the tank name.
This commit is contained in:
parent
f77e9c03fc
commit
a4cd21b811
11
src/array.c
11
src/array.c
@ -404,3 +404,14 @@ signextend (unsigned int value, unsigned int nbits)
|
||||
else
|
||||
return value & mask;
|
||||
}
|
||||
|
||||
unsigned int
|
||||
popcount (unsigned int value)
|
||||
{
|
||||
unsigned int count = 0;
|
||||
while (value) {
|
||||
value &= value - 1;
|
||||
count++;
|
||||
}
|
||||
return count;
|
||||
}
|
||||
|
||||
@ -126,6 +126,9 @@ dec2bcd (unsigned char value);
|
||||
unsigned int
|
||||
signextend (unsigned int value, unsigned int nbits);
|
||||
|
||||
unsigned int
|
||||
popcount (unsigned int value);
|
||||
|
||||
#ifdef __cplusplus
|
||||
}
|
||||
#endif /* __cplusplus */
|
||||
|
||||
@ -118,6 +118,7 @@ typedef struct shearwater_predator_tank_t {
|
||||
unsigned int pressure_reserve;
|
||||
unsigned int serial;
|
||||
char name[2];
|
||||
dc_usage_t usage;
|
||||
} shearwater_predator_tank_t;
|
||||
|
||||
struct shearwater_predator_parser_t {
|
||||
@ -254,6 +255,7 @@ shearwater_common_parser_create (dc_parser_t **out, dc_context_t *context, const
|
||||
parser->tank[i].pressure_reserve = 0;
|
||||
parser->tank[i].serial = 0;
|
||||
memset (parser->tank[i].name, 0, sizeof (parser->tank[i].name));
|
||||
parser->tank[i].usage = DC_USAGE_NONE;
|
||||
parser->tankidx[i] = i;
|
||||
}
|
||||
parser->aimode = AI_OFF;
|
||||
@ -547,6 +549,14 @@ shearwater_predator_parser_cache (shearwater_predator_parser_t *parser)
|
||||
}
|
||||
}
|
||||
}
|
||||
unsigned int gtrmode = data[offset + 29];
|
||||
if (popcount(gtrmode) >= 2) {
|
||||
for (unsigned int i = 0; i < 4; ++i) {
|
||||
if (gtrmode & (1 << i)) {
|
||||
tank[i].usage = DC_USAGE_SIDEMOUNT;
|
||||
}
|
||||
}
|
||||
}
|
||||
} else if (type == LOG_RECORD_OPENING_5) {
|
||||
if (logversion >= 9) {
|
||||
tank[0].serial = array_convert_bcd2dec (data + offset + 1, 3);
|
||||
@ -759,11 +769,7 @@ shearwater_predator_parser_get_field (dc_parser_t *abstract, dc_field_type_t typ
|
||||
break;
|
||||
}
|
||||
} else {
|
||||
if (parser->tank[flags].name[0] == 'S') {
|
||||
tank->usage = DC_USAGE_SIDEMOUNT;
|
||||
} else {
|
||||
tank->usage = DC_USAGE_NONE;
|
||||
}
|
||||
tank->usage = parser->tank[flags].usage;
|
||||
}
|
||||
break;
|
||||
case DC_FIELD_SALINITY:
|
||||
|
||||