Associate the pressure samples with the primary tank.
The primary tank, which is the tank connected to the hose and thus the tank pressure sensor, it not necessary the first tank. The correct tank index can be found by searching the array for a gas mix with a sensor id equal to one.
This commit is contained in:
parent
9db9e970cf
commit
8853a1ccd4
@ -213,6 +213,19 @@ atomics_cobalt_parser_samples_foreach (dc_parser_t *abstract, dc_sample_callback
|
||||
// Previous gas mix - initialize with impossible value
|
||||
unsigned int gasmix_previous = 0xFFFFFFFF;
|
||||
|
||||
// Get the primary tank.
|
||||
unsigned int tank = 0;
|
||||
while (tank < ngasmixes) {
|
||||
unsigned int sensor = array_uint16_le(data + SZ_HEADER + SZ_GASMIX * tank + 12);
|
||||
if (sensor == 1)
|
||||
break;
|
||||
tank++;
|
||||
}
|
||||
if (tank >= ngasmixes) {
|
||||
ERROR (abstract->context, "Invalid primary tank index.");
|
||||
return DC_STATUS_DATAFORMAT;
|
||||
}
|
||||
|
||||
unsigned int time = 0;
|
||||
unsigned int in_deco = 0;
|
||||
unsigned int offset = header;
|
||||
@ -231,7 +244,7 @@ atomics_cobalt_parser_samples_foreach (dc_parser_t *abstract, dc_sample_callback
|
||||
|
||||
// Pressure (1 psi).
|
||||
unsigned int pressure = array_uint16_le (data + offset + 2);
|
||||
sample.pressure.tank = 0;
|
||||
sample.pressure.tank = tank;
|
||||
sample.pressure.value = pressure * PSI / BAR;
|
||||
if (callback) callback (DC_SAMPLE_PRESSURE, sample, userdata);
|
||||
|
||||
|
||||