Add support for ppO2 samples.
When the PPO2 sample was introduced, we didn't take into account the fact that rebreathers usually support multiple O2 sensors. The HW OSTC supports for example three sensors. In order to support multiple values, without having to introduce a new data structure with an additional sensor id field, we simply relax the assumption of allowing only one DC_SAMPLE_PPO2 value per sample. Applications that are not prepared for multiple values, will automatically use only one of them (probably the last one).
This commit is contained in:
parent
a8f06c5c3c
commit
04ffc894c9
@ -570,6 +570,12 @@ hw_ostc_parser_samples_foreach (dc_parser_t *abstract, dc_sample_callback_t call
|
||||
return DC_STATUS_DATAFORMAT;
|
||||
}
|
||||
break;
|
||||
case 3: // ppO2
|
||||
if (info[i].size != 3 && info[i].size != 9) {
|
||||
ERROR(abstract->context, "Unexpected sample size.");
|
||||
return DC_STATUS_DATAFORMAT;
|
||||
}
|
||||
break;
|
||||
case 5: // CNS
|
||||
if (info[i].size != 1 && info[i].size != 2) {
|
||||
ERROR(abstract->context, "Unexpected sample size.");
|
||||
@ -779,6 +785,17 @@ hw_ostc_parser_samples_foreach (dc_parser_t *abstract, dc_sample_callback_t call
|
||||
sample.deco.time = data[offset + 1] * 60;
|
||||
if (callback) callback (DC_SAMPLE_DECO, sample, userdata);
|
||||
break;
|
||||
case 3: // ppO2 (0.01 bar).
|
||||
for (unsigned int j = 0; j < 3; ++j) {
|
||||
if (info[i].size == 3) {
|
||||
value = data[offset + j];
|
||||
} else {
|
||||
value = data[offset + j * 3];
|
||||
}
|
||||
sample.ppo2 = value / 100.0;
|
||||
if (callback) callback (DC_SAMPLE_PPO2, sample, userdata);
|
||||
}
|
||||
break;
|
||||
case 5: // CNS
|
||||
if (info[i].size == 2)
|
||||
sample.cns = array_uint16_le (data + offset) / 100.0;
|
||||
|
||||