Michael Keller 39bc2fe05c Import: Clean up gasmix / tank usage.
Separate the usage enums and remove the unneeded values from each.

Signed-off-by: Michael Keller <github@ike.ch>
2024-02-14 12:01:51 +13:00

358 lines
9.9 KiB
C

/*
* libdivecomputer
*
* Copyright (C) 2008 Jef Driesen
*
* This library is free software; you can redistribute it and/or
* modify it under the terms of the GNU Lesser General Public
* License as published by the Free Software Foundation; either
* version 2.1 of the License, or (at your option) any later version.
*
* This library is distributed in the hope that it will be useful,
* but WITHOUT ANY WARRANTY; without even the implied warranty of
* MERCHANTABILITY or FITNESS FOR A PARTICULAR PURPOSE. See the GNU
* Lesser General Public License for more details.
*
* You should have received a copy of the GNU Lesser General Public
* License along with this library; if not, write to the Free Software
* Foundation, Inc., 51 Franklin Street, Fifth Floor, Boston,
* MA 02110-1301 USA
*/
#ifndef DC_PARSER_H
#define DC_PARSER_H
#include "common.h"
#include "context.h"
#include "descriptor.h"
#include "device.h"
#include "datetime.h"
#ifdef __cplusplus
extern "C" {
#endif /* __cplusplus */
typedef enum dc_sample_type_t {
DC_SAMPLE_TIME,
DC_SAMPLE_DEPTH,
DC_SAMPLE_PRESSURE,
DC_SAMPLE_TEMPERATURE,
DC_SAMPLE_EVENT,
DC_SAMPLE_RBT,
DC_SAMPLE_HEARTBEAT,
DC_SAMPLE_BEARING,
DC_SAMPLE_VENDOR,
DC_SAMPLE_SETPOINT,
DC_SAMPLE_PPO2,
DC_SAMPLE_CNS,
DC_SAMPLE_DECO,
DC_SAMPLE_GASMIX,
DC_SAMPLE_TTS, // time to surface in seconds
} dc_sample_type_t;
// Make it easy to test support compile-time with "#ifdef DC_SAMPLE_TTS"
#define DC_SAMPLE_TTS DC_SAMPLE_TTS
typedef enum dc_field_type_t {
DC_FIELD_DIVETIME,
DC_FIELD_MAXDEPTH,
DC_FIELD_AVGDEPTH,
DC_FIELD_GASMIX_COUNT,
DC_FIELD_GASMIX,
DC_FIELD_SALINITY,
DC_FIELD_ATMOSPHERIC,
DC_FIELD_TEMPERATURE_SURFACE,
DC_FIELD_TEMPERATURE_MINIMUM,
DC_FIELD_TEMPERATURE_MAXIMUM,
DC_FIELD_TANK_COUNT,
DC_FIELD_TANK,
DC_FIELD_DIVEMODE,
DC_FIELD_DECOMODEL,
DC_FIELD_STRING,
} dc_field_type_t;
// Make it easy to test support compile-time with "#ifdef DC_FIELD_STRING"
#define DC_FIELD_STRING DC_FIELD_STRING
typedef enum parser_sample_event_t {
SAMPLE_EVENT_NONE,
SAMPLE_EVENT_DECOSTOP,
SAMPLE_EVENT_RBT,
SAMPLE_EVENT_ASCENT,
SAMPLE_EVENT_CEILING,
SAMPLE_EVENT_WORKLOAD,
SAMPLE_EVENT_TRANSMITTER,
SAMPLE_EVENT_VIOLATION,
SAMPLE_EVENT_BOOKMARK,
SAMPLE_EVENT_SURFACE,
SAMPLE_EVENT_SAFETYSTOP,
SAMPLE_EVENT_GASCHANGE, /* Deprecated: replaced by DC_SAMPLE_GASMIX. */
SAMPLE_EVENT_SAFETYSTOP_VOLUNTARY,
SAMPLE_EVENT_SAFETYSTOP_MANDATORY,
SAMPLE_EVENT_DEEPSTOP,
SAMPLE_EVENT_CEILING_SAFETYSTOP,
SAMPLE_EVENT_FLOOR,
SAMPLE_EVENT_DIVETIME,
SAMPLE_EVENT_MAXDEPTH,
SAMPLE_EVENT_OLF,
SAMPLE_EVENT_PO2,
SAMPLE_EVENT_AIRTIME,
SAMPLE_EVENT_RGBM,
SAMPLE_EVENT_HEADING,
SAMPLE_EVENT_TISSUELEVEL,
SAMPLE_EVENT_GASCHANGE2, /* Deprecated: replaced by DC_SAMPLE_GASMIX. */
SAMPLE_EVENT_STRING,
} parser_sample_event_t;
/* To let the compile know we have this */
#define SAMPLE_EVENT_STRING SAMPLE_EVENT_STRING
/* For backwards compatibility */
#define SAMPLE_EVENT_UNKNOWN SAMPLE_EVENT_FLOOR
typedef enum parser_sample_flags_t {
SAMPLE_FLAGS_NONE = 0,
SAMPLE_FLAGS_BEGIN = (1 << 0),
SAMPLE_FLAGS_END = (1 << 1),
SAMPLE_FLAGS_SEVERITY_MASK = (7 << 2),
} parser_sample_flags_t;
#define SAMPLE_FLAGS_SEVERITY_SHIFT 2
#define SAMPLE_FLAGS_SEVERITY_MISSING (0 << SAMPLE_FLAGS_SEVERITY_SHIFT)
#define SAMPLE_FLAGS_SEVERITY_STATE (1 << SAMPLE_FLAGS_SEVERITY_SHIFT)
#define SAMPLE_FLAGS_SEVERITY_INFO (2 << SAMPLE_FLAGS_SEVERITY_SHIFT)
#define SAMPLE_FLAGS_SEVERITY_WARN (3 << SAMPLE_FLAGS_SEVERITY_SHIFT)
#define SAMPLE_FLAGS_SEVERITY_ALARM (4 << SAMPLE_FLAGS_SEVERITY_SHIFT)
/* these are used for the types of TAGs in Shearwater PNF info events */
#define SAMPLE_FLAGS_TYPE_SHIFT 5
#define SAMPLE_FLAGS_TYPE_MASK (7 << SAMPLE_FLAGS_TYPE_SHIFT)
#define SAMPLE_FLAGS_TYPE_NONE (0 << SAMPLE_FLAGS_TYPE_SHIFT)
#define SAMPLE_FLAGS_TYPE_INTEREST (1 << SAMPLE_FLAGS_TYPE_SHIFT)
#define SAMPLE_FLAGS_TYPE_NAVPOINT (2 << SAMPLE_FLAGS_TYPE_SHIFT)
#define SAMPLE_FLAGS_TYPE_DANGER (3 << SAMPLE_FLAGS_TYPE_SHIFT)
#define SAMPLE_FLAGS_TYPE_ANIMAL (4 << SAMPLE_FLAGS_TYPE_SHIFT)
#define SAMPLE_FLAGS_TYPE_ISSUE (5 << SAMPLE_FLAGS_TYPE_SHIFT)
#define SAMPLE_FLAGS_TYPE_INJURY (6 << SAMPLE_FLAGS_TYPE_SHIFT)
typedef enum parser_sample_vendor_t {
SAMPLE_VENDOR_NONE,
SAMPLE_VENDOR_UWATEC_ALADIN,
SAMPLE_VENDOR_UWATEC_SMART,
SAMPLE_VENDOR_OCEANIC_VTPRO,
SAMPLE_VENDOR_OCEANIC_VEO250,
SAMPLE_VENDOR_OCEANIC_ATOM2
} parser_sample_vendor_t;
typedef enum dc_water_t {
DC_WATER_FRESH,
DC_WATER_SALT
} dc_water_t;
typedef enum dc_divemode_t {
DC_DIVEMODE_FREEDIVE,
DC_DIVEMODE_GAUGE,
DC_DIVEMODE_OC, /* Open circuit */
DC_DIVEMODE_CCR, /* Closed circuit rebreather */
DC_DIVEMODE_SCR /* Semi-closed circuit rebreather */
} dc_divemode_t;
/* For backwards compatibility */
#define DC_DIVEMODE_CC DC_DIVEMODE_CCR
typedef enum dc_deco_type_t {
DC_DECO_NDL,
DC_DECO_SAFETYSTOP,
DC_DECO_DECOSTOP,
DC_DECO_DEEPSTOP
} dc_deco_type_t;
typedef struct dc_salinity_t {
dc_water_t type;
double density;
} dc_salinity_t;
typedef enum dc_usage_t {
DC_USAGE_NONE, // Usage not specified
DC_USAGE_OXYGEN,
DC_USAGE_DILUENT,
DC_USAGE_OPEN_CIRCUIT,
} dc_usage_t;
typedef struct dc_gasmix_t {
double helium;
double oxygen;
double nitrogen;
dc_usage_t usage;
} dc_gasmix_t;
#define DC_SENSOR_NONE 0xFFFFFFFF
#define DC_GASMIX_UNKNOWN 0xFFFFFFFF
typedef unsigned int dc_tankinfo_t;
#define DC_TANKINFO_METRIC 1
#define DC_TANKINFO_IMPERIAL 2
// For backwards compatibility
#define DC_TANKVOLUME_NONE 0
#define DC_TANKVOLUME_METRIC DC_TANKINFO_METRIC
#define DC_TANKVOLUME_IMPERIAL DC_TANKINFO_IMPERIAL
/*
* Tank volume
*
* There are two different ways to specify the volume of a tank. In the
* metric system, the tank volume is specified as the water capacity,
* while in the imperial system the tank volume is specified as the air
* capacity at the surface (1 ATM) when the tank is filled at its
* working pressure. Libdivecomputer will always convert the tank volume
* to the metric representation, and indicate the original tank type:
*
* DC_TANKVOLUME_NONE: Tank volume is not available. Both the volume and
* workpressure will be zero.
*
* DC_TANKVOLUME_METRIC: A metric tank. The workpressure is optional and
* may be zero.
*
* DC_TANKVOLUME_IMPERIAL: An imperial tank. Both the volume and
* workpressure are mandatory and always non-zero. The volume has been
* converted from air capacity to water capacity. To calculate the
* original air capacity again, multiply with the workpressure and
* divide by 1 ATM (Vair = Vwater * Pwork / Patm).
*/
typedef enum dc_tank_usage_t {
DC_TANK_USAGE_NONE,
DC_TANK_USAGE_SIDEMOUNT,
} dc_tank_usage_t;
typedef struct dc_tank_t {
unsigned int gasmix; /* Gas mix index, or DC_GASMIX_UNKNOWN */
dc_tankinfo_t type; /* Tank type - metric/imperial and oc/cc */
double volume; /* Volume (liter) */
double workpressure; /* Work pressure (bar) */
double beginpressure; /* Begin pressure (bar) */
double endpressure; /* End pressure (bar) */
dc_tank_usage_t usage;
} dc_tank_t;
typedef enum dc_decomodel_type_t {
DC_DECOMODEL_NONE,
DC_DECOMODEL_BUHLMANN,
DC_DECOMODEL_VPM,
DC_DECOMODEL_RGBM,
DC_DECOMODEL_DCIEM,
} dc_decomodel_type_t;
/*
* Decompression model
*
* The type field contains the decompression algorithm.
*
* The (optional) conservatism field contains the personal adjustment
* setting of the algorithm. The exact interpretation depends on the
* dive computer, but the default value (zero) will typically correspond
* to the neutral setting, while a positive value is more conservative
* and a negative value more aggressive.
*
* The (optional) params field contains the parameters of the algorithm:
*
* DC_DECOMODEL_BUHLMANN: The Gradient Factor (GF) parameters low and
* high. For a pure Buhlmann algorithm (e.g. without GF enabled), both
* values are 100. If GF are enabled, but the actual parameter values
* are not available from the dive computer, both values are zero.
*/
typedef struct dc_decomodel_t {
dc_decomodel_type_t type;
int conservatism;
union {
struct {
unsigned int high;
unsigned int low;
} gf;
} params;
} dc_decomodel_t;
typedef struct dc_field_string_t {
const char *desc;
const char *value;
} dc_field_string_t;
typedef union dc_sample_value_t {
unsigned int time; /* Milliseconds */
double depth;
struct {
unsigned int tank;
double value;
} pressure;
double temperature;
struct {
unsigned int type;
unsigned int time;
unsigned int flags;
unsigned int value;
const char *name;
} event;
unsigned int rbt;
unsigned int heartbeat;
unsigned int bearing;
struct {
unsigned int type;
unsigned int size;
const void *data;
} vendor;
double setpoint;
struct {
unsigned int sensor;
double value;
} ppo2;
double cns;
struct {
unsigned int type;
unsigned int time;
double depth;
unsigned int tts;
} deco;
unsigned int gasmix; /* Gas mix index */
} dc_sample_value_t;
typedef struct dc_parser_t dc_parser_t;
typedef void (*dc_sample_callback_t) (dc_sample_type_t type, const dc_sample_value_t *value, void *userdata);
dc_status_t
dc_parser_new (dc_parser_t **parser, dc_device_t *device, const unsigned char data[], size_t size);
dc_status_t
dc_parser_new2 (dc_parser_t **parser, dc_context_t *context, dc_descriptor_t *descriptor, const unsigned char data[], size_t size);
dc_family_t
dc_parser_get_type (dc_parser_t *parser);
dc_status_t
dc_parser_set_clock (dc_parser_t *parser, unsigned int devtime, dc_ticks_t systime);
dc_status_t
dc_parser_set_atmospheric (dc_parser_t *parser, double atmospheric);
dc_status_t
dc_parser_set_density (dc_parser_t *parser, double density);
dc_status_t
dc_parser_get_datetime (dc_parser_t *parser, dc_datetime_t *datetime);
dc_status_t
dc_parser_get_field (dc_parser_t *parser, dc_field_type_t type, unsigned int flags, void *value);
dc_status_t
dc_parser_samples_foreach (dc_parser_t *parser, dc_sample_callback_t callback, void *userdata);
dc_status_t
dc_parser_destroy (dc_parser_t *parser);