1671 Commits

Author SHA1 Message Date
Jef Driesen
f6df075d51 Add support for the Genesis Centauri and Tusa TC1
Both models are compatible with the Deep Six Excursion.
2022-01-03 16:09:37 +01:00
Jef Driesen
c5dced237a Read the hardware and software version 2022-01-03 15:58:33 +01:00
Jef Driesen
5e2d376627 Report the initial setpoint in SCR mode 2022-01-03 15:54:49 +01:00
Jef Driesen
16e49eee6d Add the divemode to the layout descriptor 2022-01-03 15:54:49 +01:00
Jef Driesen
70411048e5 Re-order the fields in the layout descriptor
The new order of the fields matches the physical memory layout more
closely.
2022-01-03 15:54:39 +01:00
Jef Driesen
af03e39383 Add support for the Crest CR-4
The Crest CR-4 is compatible with the Deep Six Excursion.
2021-11-19 08:26:19 +01:00
Michael Andreen
93fe31eef5 Garmin: Fix gas change event parsing
The gas mixes are numbered from 0 and up and the gas change event uses
this number directly, so no need to subtract one.

Signed-off-by: Michael Andreen <michael@andreen.dev>
2021-11-17 11:58:14 +01:00
Jef Driesen
cd0f42804a Ignore unsupported BLE handshake
For some BLE enabled models, like the Oceanic Pro Plus X, Aqualung
i750TC, Sherwood Sage and Sherwood Beacon, the BLE handshake command
is not supported and therefore disabled.

However, based on a bug report by a user with two Aqualung i770R dive
computers, this detection mechanism based on the dive computer model
number isn't sufficient. Allthough the two devices have the exact same
firmware version (2A), the handshake command only works on the newest
unit, and fails with a NAK response on the oldest unit.

Remove the model based detection and always try to send the handshake
command and rely on the NAK response to ignore the failure instead. An
additional advantage is that we no longer have to (manually) maintain a
list with the model numbers where the handshaking is known to fail.
2021-10-20 15:02:57 +02:00
Jef Driesen
ba4a119a4f Detect NAK response packets
When the dive computer receives a command it doesn't support, it sends
back a single byte NAK (0xA5) packet instead of the expected ACK byte
(0x5A) at the start of the packet. Retrying is pointless in this case,
because the next attempt will also fail. Instead, return immediately
with an appropriate error code, and let the upper layers handle the
unsupported command.

Note that the detection is currently only enabled for BLE communication.
2021-10-20 15:02:34 +02:00
Jef Driesen
9ff6e5caad Remove the initial gas switch
The Cressi Drake is a freedive computer and does not support gas
switches.
2021-10-13 11:06:26 +02:00
Jef Driesen
a8bcfb998b Restore the original standard gravity factor
The Uwatec/Scubapro dive computers are confirmed to internally use the
approximated standard gravity (10.0 m/s²) for the depth conversion.
Allthough this is technically wrong, users expect to get the same depth
values as their dive computer shows.

This partially reverts commit cfc9ddc380bdc5616893fc2af4e05204b5500ea2.
2021-10-03 11:37:59 +02:00
Jef Driesen
1c39c68203 Add support for the Mares Puck Pro +
The Mares Puck Pro + is compatible with the previous Puck Pro. Both
models can't even be distinguished because they share the same model
number and use the same product name in the version packet.
2021-09-28 12:14:10 +02:00
Jef Driesen
7e075eb959 Add support for Mares Smart Air freedives
The Mares Smart Air supports a freedive mode, which uses a different
data format compared to the scuba dives.
2021-09-14 21:33:47 +02:00
Jef Driesen
e52468e0c3 Use a layout descriptor
Replace hardcoded constants with a layout descriptor. This reduces the
amount of model specific conditions, and makes it easier to add support
for new models.
2021-09-14 21:32:48 +02:00
Jef Driesen
1a4798792e Use the divetime stored in the header
There is no need to calculate the total time from the pseudo profile,
because the dive time is also stored in the header.
2021-09-14 21:32:48 +02:00
Jef Driesen
c4b694fdb1 Fix the salinity parsing
The parser->mode field is only initialized at the end of the function.
The result is that the current code always used the default value
(zero). Inside the function itself, the local variable should be used
instead.
2021-09-14 21:32:31 +02:00
Linus Torvalds
b6df353752 Merge branch 'master' of git://github.com/libdivecomputer/libdivecomputer into Subsurface-DS9
Merge upstream libdivecomputer updates by Jef Driesen.

Minor fixups, and add ID for Cressi Neon.

* git://github.com/libdivecomputer/libdivecomputer:
  Add support for the Cressi Neon
  Use symbolic constant for invalid value
  Remove duplicate macro definition
  Add BLE support for the Aqualung i750TC
  Exclude the surface time from the dive time
2021-08-20 18:28:23 -07:00
Dirk Hohndel
3057ac79c2 Mares Icon HD protocol: add serial as string
I verified that the unsigned integer in the devinfo header actually matches the
serial number shown in the "About" dialog on the device - so let's add this as
extra data string and make it user visible (and also allow Mares Icon HD style
devices to be reliably distinguished in Subsurface).

Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
2021-08-20 11:03:12 -07:00
Dirk Hohndel
f2cc4ab7ef Suunto Vyper protocol: add serial as string
I verified that the unsigned integer in the devinfo header actually matches the
serial number printed on the device - so let's add this as extra data string
and make it user visible (and also allow Suunto Vyper style devices to be
reliably distinguished in Subsurface).

Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
2021-08-20 11:01:30 -07:00
Ryan Gardner
75f260a941 Add support for the Deep Six Excursion
Based on original work and code by Ryan Gardner, with some additional
improvements and integration into libdivecomputer by Jef Driesen.
2021-08-17 22:38:53 +02:00
Linus Torvalds
643b4271f6 EON Steel: support new gas change data from newer firmware
It seems that Suunto extended the gas change information in FW 2.5, and
added events and fields for when you create and delete gas mixes under
water.

The parses the relevant new information to get gas switches working
again, and to also add the information about gas creation and deletion
events.

Signed-off-by: Linus Torvalds <torvalds@linux-foundation.org>
2021-08-17 08:14:40 -10:00
Jef Driesen
e0409a9496 Add support for the Cressi Neon
The Cressi Neon appears to be compatible with the Goa and Cartesio, with
just a different model number.
2021-08-17 17:53:16 +02:00
Jef Driesen
70d3cdcc08 Use symbolic constant for invalid value 2021-08-16 15:26:45 +02:00
Linus Torvalds
e7da5acff3 Garmin: add extra-info for serial number and firmware version
In proper string format that matches what the Garmin reports on the
"About" screen.

Signed-off-by: Linus Torvalds <torvalds@linux-foundation.org>
2021-08-15 16:40:02 -10:00
Jef Driesen
03974481b0 Remove duplicate macro definition 2021-08-09 10:04:17 +02:00
Jef Driesen
58d410b1a2 Add BLE support for the Aqualung i750TC
The Aqualung i750TC supports BLE, but the BLE handshaking fails and
needs to be disabled.
2021-08-08 20:34:49 +02:00
Jef Driesen
38bd51e63a Exclude the surface time from the dive time
Like most dive commputers, the Mares Genius uses a surface timeout to
detect the end of the dive. But since there is no explicit dive time
field stored, the total dive time is based on the number of samples,
which includes this surface time at the end of the dive. However, the
dive time displayed by the dive computer (and also the Mares
DiveOrganizer application) does not include this surface time.

For older firmware versions the value is hardcoded to 3 minutes, but
starting with the newer v01.02.00 firmware the value is configurable and
stored in the settings. To detect whether the setting is available, we
need to check the profile version instead of the header version. That's
because the header appears to be generated on-the-fly during the
download, and thus the header version also changes for dives recorded
prior to the firmware update.

For all other models, also take into account a hardcoded timeout of 3
minutes.
2021-07-26 17:20:16 +02:00
Linus Torvalds
2ef285faf3 Merge branch 'crashFix' of https://github.com/subsurface/libdc into Subsurface-DS9
Merge mtp_device cleanup from Dirk Hohndel.

* 'crashFix' of https://github.com/subsurface/libdc:
  cleanup: ensure mtp_device field is 0
2021-07-19 14:37:46 -07:00
Linus Torvalds
3e87ed050c Merge branch 'master' of git://github.com/libdivecomputer/libdivecomputer into Subsurface-DS9
Merge upstream libdivecomputer updates by Jef Driesen:

 - fix HW Sport and Mares Genius firmware update

 - Windows Visual Studio build updates

 - Various parser updates:
    - sporasub depth, salinity and sample rate parsing
    - Atomics Cobalt atmospheric pressure parsing
    - unit cleanups (Uwatec, McLean Extreme)

* git://github.com/libdivecomputer/libdivecomputer:
  Some more fixes for the new Mares Genius firmware
  Implement the salinity field
  Fix the sample rate parsing
  Add support for the new Mares Genius firmware
  Use the correct standard gravity factor
  Use SI units internally
  Fix negative depth values
  Move the unit conversion to the last moment
  Implement the atmospheric pressure field
  Always use the stored atmospheric pressure
  Add a CI job to build with Visual Studio
  Migrate to Visual Studio 2013 (or newer)
  Emit events when downloading a memory dump
  Fix the depth decoding
  Add library dependencies in windows build
  Fix the hwOS Sport firmware upgrade
  Post release version bump to 0.8.0
2021-07-19 14:30:55 -07:00
Jef Driesen
927362354d Some more fixes for the new Mares Genius firmware
The changes in commit 5cb527d53ca88ac692beb55288172fc1003975fa to
support the new Mares Genius firmware v01.02.00 were incomplete.

For dives recorded prior to the firmware upgrade, only the header
version changed from 0.0 to 1.1, while the profile version remained the
same. But for dives recorded after the firmware upgrade, the profile
version also changed from 0.2 to 1.0.

The known header and profile object versions (indicated as
type.major.minor) are now:

  Model   | Firmware | Header | Profile
  ========|==========|========|=========
  Genius  | 1.0.x    | 1.0.0  | 0.0.2
  Genius  | 1.2.0    | 1.1.1  | 0.1.0
  Horizon | 1.7.28   | 1.0.1  | 1.0.2

To simplify the object version check, all versions below a certain upper
limit are now considered supported.
2021-07-13 22:45:40 +02:00
Jef Driesen
5bb6257acb Implement the salinity field
The 4th bit of the settings byte contains the salinity setting (salt or
fresh water).
2021-07-13 00:00:26 +02:00
Jef Driesen
060c0b7215 Fix the sample rate parsing
The byte at offset 0x1A appears to be some settings byte, containing not
only the sample rate index, but also some other values in the higher
bits. Except for the 4th bit, which contains the salinity setting, the
meaning of those higher bits remains unknown. Since the sample rate is
limited to only 4 possible values, 2 bits are sufficient for encoding
the sample rate index. The 3th bit might contain some other setting, or
be reserved for future sample rates.
2021-07-12 23:52:56 +02:00
Dirk Hohndel
eaeb5c5341 cleanup: ensure mtp_device field is 0
We explicitly check that field for 0 before dereferencing it. Let's make sure
that it always starts out being 0 - otherwise we'll get a potential crash here.

Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
2021-07-12 14:49:13 -07:00
Jef Driesen
5cb527d53c Add support for the new Mares Genius firmware
The new Mares Genius firmware v01.02.00 has a header which is 10 bytes
larger. This difference is indicated with a change in the major version
from 0 to 1.
2021-07-06 17:43:41 +02:00
Jef Driesen
cfc9ddc380 Use the correct standard gravity factor
For manual depth calculations by divers, the standard gravity is
often approximated as 10.0 (e.g. 1 bar corresponds to 10 meter), but
libdivecomputer prefers to use the exact value of 9.80665 m/s².

For the McLean Extreme, it has been confirmed that the device also uses
the correct standard gravity internally for the conversion of the sample
depth.
2021-07-06 16:16:18 +02:00
Jef Driesen
cffda88ae8 Use SI units internally
Prefer SI units for internal constants (e.g. density) and calculations.
This results in more consistent conversion formulas across the different
backends.

For the Uwatec backend, this changes makes it also much more visible
that the unit for the depth is either 1 millibar (maximum depth) or 2
millibar (sample depth).
2021-07-06 16:16:18 +02:00
Jef Driesen
b186846a9e Fix negative depth values
The difference between two unsigned integers can be negative. To avoid
ending up with some very large positive values, an explicit cast to a
signed integer is required.

Depths are normally expected to be always positive, but near the surface
the pressure will be very close to the atmospheric pressure. Therefore
small negative values are not unusual.
2021-07-06 16:16:18 +02:00
Jef Driesen
da2446283a Move the unit conversion to the last moment
Processing the data in device units, and performing the unit conversion
only at the very last moment, avoids the need for intermediate floating
point math and thus possible rounding errors. In practice this is not
really an important issue, except for some case where a negative zero
value was returned.
2021-07-06 16:16:18 +02:00
Jef Driesen
6645b3f5e4 Implement the atmospheric pressure field 2021-07-06 16:16:18 +02:00
Jef Driesen
c8bd477c84 Always use the stored atmospheric pressure
The correct atmospheric pressure is measured and recorded by the dive
computer. There is no need to replace the correct value with some other
value.
2021-07-06 16:16:18 +02:00
Jef Driesen
9106250a53 Emit events when downloading a memory dump 2021-06-25 17:17:20 +02:00
Jef Driesen
449b65cf1b Fix the depth decoding
With just 12 bits, the depth values are limited to at most 40.95m.
However for some deeper dives, this appears to be wrong. The next two
higher bits, which were previously unknown, are also part of the depth.
This increases the maximum depth to 163.83m.
2021-06-25 17:16:33 +02:00
Jef Driesen
fba5676b78 Fix the hwOS Sport firmware upgrade
Support for the S_BLOCK_WRITE2 command is only available since the hwOS
Tech firmware v3.09 and the hwOS Sport firmware v10.64. In commit
9e92381be48866f3f13a11e98d59962575bb5ad3 it was enabled for all firmware
versions newer than v3.09, causing the firmware upgrade to fail for
older hwOS Sport firmware versions.

Reported-by: Anton Lundin <glance@acc.umu.se>
2021-05-26 12:04:18 +02:00
Linus Torvalds
87d484e9a8 Merge tag 'v0.7.0' into Subsurface-DS9
Update to the v0.7.0 release.

Only a couple of trivial changes from the last development version we merged with:

 - add new product ID for the Sherwood Amphos 2.0

 - make the example app use the product name and not vendor name for the
   McLean Extrme

* tag 'v0.7.0':
  Release version 0.7.0
  Use the product name as the family name
  Add support for the Sherwood Amphos 2.0
2021-05-08 08:53:48 -07:00
Nick Shore
37c4203537 Add support for the Sherwood Amphos 2.0 2021-05-02 16:08:10 +02:00
Linus Torvalds
9ab0800c00 Merge git://github.com/libdivecomputer/libdivecomputer into Subsurface-DS9
Merge upstream updates from Jef:

 - add suppoort for various new variants of existing dive computers:

    + Suunto Eon Steel Black, and new variant of Zoop Novo

    + Sherwood Beacon

    + new Shearwater Perdix AI model number

 - add new Sporasub SP2 support

 - various minor fixes and updates

* 'master' of git://github.com/libdivecomputer/libdivecomputer: (22 commits)
  Add support for a new Suunto Zoop Novo variant
  Add support for the EON Steel Black
  Add support for the Sporasub SP2
  Fix an overflow in the progress events
  Use a common sleep implementation
  Fix the clang compiler flag detection
  Add Github Actions CI builds and releases
  Show a summary after configuration
  Extend the OS detection to non Windows platforms
  Implement the ndl/deco sample
  Fix the maximum depth
  Mark the McLean Extreme as supporting BLE
  Fix -Wcast-qual compiler warning
  Mark the new iX3M 2021 models as supporting BLE
  Add support for the Sherwood Beacon
  Remove the infinite timeout
  Simplify the loop for reading the packet header
  Add a new Perdix AI hardware type
  Fix the McLean Extreme fingerprint feature
  Perform the check for the NULL key earlier
  ...
2021-04-22 08:40:35 -07:00
Nick Shore
d85d8811f0 Add support for a new Suunto Zoop Novo variant 2021-04-20 09:58:20 +02:00
Nick Shore
76d225dcfc Add support for the EON Steel Black 2021-04-20 09:30:01 +02:00
Jef Driesen
6ef72ab420 Add support for the Sporasub SP2
The Sporasub SP2 uses a very simple communication protocol and memory
layout, but with some unusual aspects:

Dives are artifically limited to a maximum of 6000 samples.

Unlike all other dive computers, the dives are not stored in some kind
of ringbuffer structure. Once the memory is full, no new dives can be
recorded. The existing dives need to be erased first, and the dive
computer will start recording again at te start of the memory area. The
Sporasub application has an "Auto-clear watch memory after data
transfer" feature for this purpose.

I didn't implement a more efficient download algorithm because
downloading a full memory dumps takes less than 10 seconds.
2021-04-15 16:47:59 +02:00
Jef Driesen
1418766a1a Fix an overflow in the progress events
The maximum value for the progress events is based on the amount of the
flash memory available for storing the dives. But the 8 byte serial
number is not stored inside the dive data, and is added dynamically
during the data transfer. This extra data needs to be taken into account
to avoid overflowing the progress events and trigger an assert in the
code.
2021-04-08 17:27:43 +02:00