For dive computers where the reference time (epoch) of the device is
unknown, libdivecomputer uses the current time of the device (devtime)
and the host system (systime) to synchronize both clocks.
Currently, both timestamps are passed directly to the constructor of the
parser. With the new public function, the application can adjust the
timestamps afterwards.
Some dive computers store the depth as an absolute pressure value (in
bar). To convert to a depth value (in meters), the atmospheric pressure
and water density are required. For dive computers that do not have
those values available, libdivecomputer uses a default value. With the
new public api functions, applications can adjust those default values.
Some dive computers already provided a backend specific calibration
function. Those functions are now deprecated. They are kept around to
maintain backwards compatibility for now, but they will be removed in
the next version.
Allthough most dive computers always use local time and don't support
timezones at all, there are a few exceptions. There are two different
sources of timezone information:
- Some of the newer Uwatec/Scubapro devices use UTC internally and also
support a timezone setting. This UTC offset is currently taken into
account to obtain the dive date/time, but the UTC offset itself is
lost.
- Uwatec/Scubapro and Reefnet devices rely on the clock of the host
system to synchronize the internal device clock and calculate the
dive date/time. The consequence is that the resulting date/time is
always in the timezone of the host system.
In order to preserve this timezone information, the dc_datetime_t
structure is extended with a new "timezone" field, containing the UTC
offset in seconds. Devices without timezone support will set the field
to the special value DC_TIMEZONE_NONE.
The dc_datetime_localtime() and dc_datetime_gmtime() functions will
automatically populate the new field with respectively the local
timezone offset and zero. The dc_datetime_mktime() function will take
into account the new timezone field for the conversion to UTC. The
special value DC_TIMEZONE_NONE is interpreted as zero.
The Cochran Commander TM appears to be a first generation Commander with
limited storage and function compared to later models.
The main differences are:
- The TM doesn't support high-speed transfer so use the 0x05 read
command and don't change to a higher baud rate. Still reset to 9600
to wait for the heartbeat.
- The TM has a different config command (one byte).
- The TM has only one config page.
Newer cochran DCs record a gas change event at the begining of a
dive. The code creates a gas change before processing samples so
with newer DCs this resulted in duplicate events.
This adds support for older Cochran Commander dive computers,
specifically Commanders with serial numbers prior to 21000.
This also renames "Commander" model to "Commander II" and
adds "Commander I" to refer to pre-21000 models.
The vendor_product_parser_create() and vendor_product_device_open()
functions should be called indirectly, through the generic
dc_device_open() and dc_parser_new() functions. And the
vendor_product_extract_dives() functions are internal functions that
should never have been part of the public api in the first place.
For dives with multiple gas mixes, an application doesn't have enough
info to figure out which one is the initial gas mix. Usually it's the
first gas mix, but that's not guaranteed. Reporting the intial gas mix
on the first sample avoids this problem.