Shearwater: extract tank sensor data for log version 7
The first dive computer to support this is the Perdix AI. Interestingly, this keeps track of two sensors at all times. I haven't seen data with two sensors active, yet. [Jef Driesen: Update to the latest documentation.] Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
This commit is contained in:
parent
9f754dc563
commit
7f22f4ac86
@ -522,6 +522,34 @@ shearwater_predator_parser_samples_foreach (dc_parser_t *abstract, dc_sample_cal
|
||||
sample.deco.time = data[offset + 9] * 60;
|
||||
if (callback) callback (DC_SAMPLE_DECO, sample, userdata);
|
||||
|
||||
// for logversion 7 and newer (introduced for Perdix AI)
|
||||
// detect tank pressure
|
||||
if (parser->logversion >= 7) {
|
||||
// Tank pressure
|
||||
// Values above 0xFFF0 are special codes:
|
||||
// 0xFFFF AI is off
|
||||
// 0xFFFE No comms for 90 seconds+
|
||||
// 0xFFFD No comms for 30 seconds
|
||||
// 0xFFFC Transmitter not paired
|
||||
// For regular values, the top 4 bits contain the battery
|
||||
// level (0=normal, 1=critical, 2=warning), and the lower 12
|
||||
// bits the tank pressure in units of 2 psi.
|
||||
unsigned int pressure = array_uint16_be (data + offset + 27);
|
||||
if (pressure < 0xFFF0) {
|
||||
pressure &= 0x0FFF;
|
||||
sample.pressure.tank = 0;
|
||||
sample.pressure.value = pressure * 2 * PSI / BAR;
|
||||
if (callback) callback (DC_SAMPLE_PRESSURE, sample, userdata);
|
||||
}
|
||||
pressure = array_uint16_be (data + offset + 19);
|
||||
if (pressure < 0xFFF0) {
|
||||
pressure &= 0x0FFF;
|
||||
sample.pressure.tank = 1;
|
||||
sample.pressure.value = pressure * 2 * PSI / BAR;
|
||||
if (callback) callback (DC_SAMPLE_PRESSURE, sample, userdata);
|
||||
}
|
||||
}
|
||||
|
||||