Shearwater: Fix Sensor Calibration for DiveCAN Controllers.
Remove the code that forces hiding of O2 sensor readings despite the sensors being reported as properly calibrated by the divecomputer. This fixes the problem of no sensor readings showing on DiveCAN controllers due to the fact that the sensor calibration values are returned as defaults on these devices. Also increase the timeout for data reads - this seems to improve the reliability when reading logs of long dives. Signed-off-by: Michael Keller <github@ike.ch>
This commit is contained in:
parent
89221475cf
commit
6e65428fc8
@ -58,8 +58,8 @@ shearwater_common_setup (shearwater_common_device_t *device, dc_context_t *conte
|
||||
return status;
|
||||
}
|
||||
|
||||
// Set the timeout for receiving data (3000ms).
|
||||
status = dc_iostream_set_timeout (device->iostream, 3000);
|
||||
// Set the timeout for receiving data (12s).
|
||||
status = dc_iostream_set_timeout (device->iostream, 12 * 1000);
|
||||
if (status != DC_STATUS_SUCCESS) {
|
||||
ERROR (context, "Failed to set the timeout.");
|
||||
return status;
|
||||
@ -696,6 +696,9 @@ dc_status_t shearwater_common_get_model(shearwater_common_device_t *device, unsi
|
||||
|
||||
// Convert and map to the model number.
|
||||
unsigned int hardware = array_uint16_be (rsp_hardware);
|
||||
|
||||
DEBUG(device->base.context, "Hardware type: 0x%04x", hardware);
|
||||
|
||||
switch (hardware) {
|
||||
case 0x0101:
|
||||
case 0x0202:
|
||||
|
||||
@ -418,7 +418,6 @@ shearwater_predator_parser_cache (shearwater_predator_parser_t *parser)
|
||||
dc_parser_t *abstract = (dc_parser_t *) parser;
|
||||
const unsigned char *data = parser->base.data;
|
||||
unsigned int size = parser->base.size;
|
||||
const char *ppo2_source = NULL;
|
||||
|
||||
if (parser->cached) {
|
||||
return DC_STATUS_SUCCESS;
|
||||
@ -728,7 +727,7 @@ shearwater_predator_parser_cache (shearwater_predator_parser_t *parser)
|
||||
dc_field_add_string_fmt(&parser->cache, "Logversion", "%d%s", logversion, pnf ? "(PNF)" : "");
|
||||
|
||||
// Cache sensor calibration for later use
|
||||
unsigned int nsensors = 0, ndefaults = 0;
|
||||
unsigned int nsensors = 0;
|
||||
unsigned int base = parser->opening[3] + (pnf ? 6 : 86);
|
||||
for (size_t i = 0; i < 3; ++i) {
|
||||
unsigned int calibration = array_uint16_be(data + base + 1 + i * 2);
|
||||
@ -741,25 +740,11 @@ shearwater_predator_parser_cache (shearwater_predator_parser_t *parser)
|
||||
parser->calibration[i] *= 2.2;
|
||||
}
|
||||
if (data[base] & (1 << i)) {
|
||||
if (calibration == 2100) {
|
||||
ndefaults++;
|
||||
}
|
||||
nsensors++;
|
||||
}
|
||||
}
|
||||
if (nsensors && nsensors == ndefaults) {
|
||||
// If all (calibrated) sensors still have their factory default
|
||||
// calibration values (2100), they are probably not calibrated
|
||||
// properly. To avoid returning incorrect ppO2 values to the
|
||||
// application, they are manually disabled (e.g. marked as
|
||||
// uncalibrated).
|
||||
WARNING (abstract->context, "Disabled all O2 sensors due to a default calibration value.");
|
||||
parser->calibrated = 0;
|
||||
ppo2_source = "voted/averaged";
|
||||
} else {
|
||||
parser->calibrated = data[base];
|
||||
ppo2_source = "cells";
|
||||
}
|
||||
|
||||
parser->calibrated = data[base];
|
||||
|
||||
// Get the dive mode from the header (if available).
|
||||
if (logversion >= 8) {
|
||||
@ -830,8 +815,6 @@ shearwater_predator_parser_cache (shearwater_predator_parser_t *parser)
|
||||
case M_CC:
|
||||
case M_CC2:
|
||||
DC_ASSIGN_FIELD(parser->cache, DIVEMODE, DC_DIVEMODE_CCR);
|
||||
if (ppo2_source)
|
||||
dc_field_add_string(&parser->cache, "PPO2 source", ppo2_source);
|
||||
break;
|
||||
case M_SC:
|
||||
DC_ASSIGN_FIELD(parser->cache, DIVEMODE, DC_DIVEMODE_SCR);
|
||||
|
||||
Loading…
x
Reference in New Issue
Block a user